20.6.8.5. JMAG RT

The JMAG RT block is for co-simulation between CoLink and JMAG RT . This block needs to use JMAG RT Model. The file extension is rtt.

20.6.8.5.1. JMAG RT Subsystem

  • JMAG RT Subsystem

../_images/jmag_rt_subsystem_block.png
  • JMAG RT Subsystem Input/Output

Table 20.69 Inputs of JMAG-RT Subsystem

Input Parameter(s)

Description

Va, Vb, Vc

Input Voltage.

Tm

Mechanical load torque.

Coil Temp

Coil Temperature.

Magnet Temp

Magnet Temperature

Coil Temp

Coil temperature.

DC Voltage

DC bus voltage which is used to refer the AC Copper loss look up table and harmonic iron loss look up table.

Carrier Freq

Carrier frequency which is used to refer the AC Copper loss look up table and harmonic iron loss look up table.

Table 20.70 Outputs of JMAG-RT Subsystem

Input Parameter(s)

Description

is_abc

Stator line currents.

thetam

Rotor Angle.

wm

Rotor speed.

Te

Electromagnetic torque.

Fabc

Coil Flux.

LdLq

Coil d, q inductance.

Iron loss

Sumation of Eddy loss and Hysteresis loss.

User Specified Parameters

Parameters in RTT file.

DC Copper Loss

DC component of coil copper loss.

AC Copper Loss

AC component of coil copper loss.

  • Inside of JMAG-RT Subsystem

../_images/jmag_rt_subsystem.png

20.6.8.5.2. JMAG RT Block

  • JMAG RT Block

../_images/jmag_rt_block.png
  • JMAG RT Block Input/Output

Table 20.71 Inputs of JMAG-RT Block

Input Parameter(s)

Description

Va

Voltage Input A.

Vb

Voltage Input B.

Vc

Voltage Input C.

Theta

Rotor Displacement

Coil Temp

Coil temperature.

Magnet Temp

Magnet Temperature.

DC Voltage

DC bus Voltage

Carrier Freq

Carrier Frequency

Table 20.72 Outputs of JMAG-RT Block

Output Parameter(s)

Description

Ia

Current Output A.

Ib

Current Output B.

Ic

Current Output C.

Torque

Rotor Torque.

EddyLoss

Eddy Loss.

HysLoss

Hysteresis Loss.

Fu

Coil Flux U Phase.

Fv

Coil Flux V Phase.

Fw

Coil Flux W Phase.

Ld

Inductance d.

Lq

Inductance q.

Magnet Temp

Magnet Temperature.

DC Copper Loss

DC component of coil copper loss .

AC Copper Loss

AC component of coil copper loss.

User Parameters

User Parameters which are defined in RTT file.

20.6.8.5.3. JMAG RT Block Dailog

../_images/jmag_rt_dialog.png
  • Highlight Items

    1. RTT File Input box.

    2. There are three types of accuracy: LdLq, Spatial Harmonic, and Flux Integral. To use each type of accuracy, the relevant items need to be defined within the RTT file.

    3. Decide whether to use Iron Loss table data or not. If select the #3 . Table from JMAG considering PWM Carrier Frequency, specify filter inductance is available.

    4. When the “Set values on manually check” box is checked, you can configure certain coefficients and turns of the coil. The values related to temperature located below can be configured when the “Use Temperature Correction Checkbox” is checked.

    5. To calculate Temperature Correction, this checkbox must be checked.

    6. There are two types for table data Interpolation. Linear and Cubic. Linear is default option.

  • Remains

    • Use AC Copper Loss Equivalent Resistance Table : To active AC Copper loss, this checkbox should be checked.

    • Resistance of Coil : Relate with working value of R.

    • Offset Angle : Initial displacement of rotor.