10.2.3. MSC/NASTRAN Interface

The user can generate input files that can make an rfi file through Modal Analysis or CMS Analysis in MSC/Nastran. Only following elements are supported in RecurDyn/RFlex.

Table 10.1 Supported MSC/NASTRAN Element Library

Type

Nastran elements

1DElement

CBAR, CBEAM, CBEND, CONROD, CROD, CTUBE

2DElement

CTRIA3, CTRIA6, CQUAD4, CQUAD8, CSHEAR

3DElement

CTETRA, CPENTA, CHEXA, CPYRAM

RigidElement

RBAR, RBE2, RBE3, RROD, CBUSH, CBUSH1D, CELAS1, CELAS2

MassElement

CONM1, CONM2

Table 10.2 Supported MSC/NASTRAN Material/Property Library

Type

Supported Material / Property

Material

MAT1, MAT2, MAT8, MAT9

Property

PBEAM, PBEND, PBAR, PROD, PTUBE PSHELL,
PSHEAR PSOLID PMASS, PELAS PBUSH, PBUSH1D