47.2.2.2. Executing the RecurDyn Solver
RecurDyn Windows solver is ready to run once the two inputs files are created and moved to a working directory on the Windows computer.
To use the Windows console (recommended)
Type the following on the Windows console (with/without the file extension):
"<Install Dir>\Bin\Solver\RDSolverRun.exe" rmd_file rss_file
To use the executable file (not recommended)
Execute the RDSolverRun.exe file. So, you can see the following contents.
______________________________________________________ RecurDyn Program Menu (Version #) ___________________________________________ Build Date Build Time ___________________________________________ ^^Enter your option STA or STOP^^
Type the STA: You can see the following contents.
^^Enter the name of the Auto-Command File or EXIT or ENTER^^
Type the name of the Auto-Command File: You can simulate models using a rcf file. The rcf file is simply the rss file with the name of the rmd file added to the first line.
An example of the rcf file is:
Model_1.rmd SIM/DYN, END = 5, STEP = 100 STOP
Press the EXIT key: You can run exit.
Press the ENTER key: You can see the following contents.
^^Enter RMD filename or STOP^^
Type the name of the RMD file: You have to input the name of the rmd file as the absolute path like the following contents.
E:\Test\SimpleTest\Model
After then, you can see the following contents. Type the command wanted.
** ENTER COMMAND:
An Example of command is:
line1: sim/sta,end=1.0,step=100 line2: sim/dyn,end=5.0,step=100 line3: stop line4: sim/sta,end=1.0,step=100 line5: sim/dyn,end=5.0,step=100 line6: stop
There are two parts of command line group. From line1 to line3 is a list of scenarios like a rss file. The real execute command is line4 to line6. To see more information about commands supported, click here.